Peripheral Crate Electronics
Testing,
Installation and Commissioning Procedures
Run Hyper-DAQ Session
The first panel of the testing session
will now appear.
The top YELLOW section is used to set up
the crate.
Input operator(s) name(s)
Input run number
Crate Tests
Calibration Runs
Crate Configuration
This section lists the crate slots
vertically. Horizontally is the board ID
then then the test types
The first type is board status and
requires no communication between the target board and any other boards except
the CC. All the communication is via the
VMB back plane.
DMB Status >> panel pops up
when you click on the ‘DMB Status’ for a particular slot
Top box >> DMB ID’s
>> read from the DMB in the target slot
Bottom box >> Voltages and
Temperatures >>, those shown in green are read from the DMB, most read
from the CFEB’s
DMB fpga user id >>
should be 48547182
If not,
click DMB Utilities, click Load Firmware (right
now has file hard coded)
CFEB Status >> this panel shows the
return when there is NO CSC connected to the DMB.
TMB Status >>
for this panel there is NO CSC connected to the TMB
Firmware date should be 02/27/2006
If not,
click TMB Utilities, choose file to load,
click Load Firmware (right now has file hardcoded to
be ./tmb2005e02272006.svf, no matter what you choose)
ALCT Status >>
DMB Tests >> Tests 9 and 10 involve
the DMB only and should succeed without a CSC connected. All the other tests require the CSC (CFEB’s) be connected to properly complete.
DMB Utils
>>
DMB Turn OFF (ON)
DMB Print Counters >>
DMB Load Firmware >> The DMB
firmware downloaded is hard wired and clicking the button will download it to
the board
CFEB to … >> use this button to chose
which CFEB to download, and to download the firmware to that CFEB.
TMB Tests >> This
panel is used to run the TMB tests.
TMB Utils
>>
Crate Tests >> These
tests involve ONE CSC > a single set of DMB, TMB, and RAT along with the CREB’s and ALTC’s on a CSC. The CSC must be connected and operating properly
to do any of these tests.
MPC Status >> The
firmware version should be 20-10-2005
CCB Status >>
CCB Utils
>>
Read Register … >> reads registers in the CCB
Hard Reset sends a hard reset to the PC
via the CCB
RunHyperDAQSession.htm 3-March-2006 Fred Borcherding